switching angle

English to Swedish Tech/Engineering Electronics / Elect Eng electrical/commutated motor
The text concerns a control system for the speed a vacuum cleaner motor. One parameter is the switching angle and to be honest I can not understand if it concerns the motor or outside the vacuum cleaner. like the angle of the nozzle against the floor.
Proposed translations (Swedish)
3 tändvinkel

Discussion

meirs Aug 3, 2010:
switching angle I suggest that you translate it as the Swedish equivalent of "switching ON angle". Anyone that understands the subject matter will be able to understand what is all about. Alternately, look up Swedish texts dealing with "thyristor switching" or "SCR switching" (SCR = Silicon Controlled Rectifier) - you will most certainly find the expression there.
O3C (asker) Aug 3, 2010:
I have not much to give you: some variables used to to control the motor are: "..the motor current, switching angle and rotational speed are indirect characteristic variables."
meirs Aug 3, 2010:
More context is needed In any case, electrical (AC) power is normally switched electronically using thyristors. AS AC power is a sinewave (sinus wave) running from 0 to 360 degrees each cycle. Electrical power is controlled by firing (switching) thyristors ON at a certain angle of thr sinewave.

Proposed translations

4 hrs
Selected

tändvinkel

Provided the reference information given by the other colleagues is correct in your context, which I believe, I suggest "tändvinkel". 17 hits on Google for Swedish tyristor +tändvinkel.
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Stort tack, det verkar logiskt."

Reference comments

18 mins
Reference:

Switching angle

Transformer inrush
When a transformer is energised, it may draw a high magnitude transient current from the supply causing a temporary voltage dip. This current, characterised as being almost entirely unidirectional, rises abruptly to its maximum value in the first half-cycle and then decays until the normal steady-state magnetizing conditions are reached. The magnitude and duration of the inrush current depends upon the following all of which can be represented using a PSCAD model:


•the point on the voltage wave at the instant the transformer is energised (i.e. switching angle)
Something went wrong...