English to Spanish: Image-Guided Surgery General field: Medical Detailed field: Medical (general)
Source text - English VV spine is a wireless navigation system, which means that unlike traditional navigation systems, no cables, batteries, or foot switches are required. Instead, the system uses passive marker spheres, and two infrared cameras which emit infrared flashes.
The passive marker spheres are mounted to each surgical instrument, and to a reference array which is securely attached to the patient’s bone structure. Each passive marker sphere reflects the infrared flashes from the cameras, creating an individual infrared reflection image.
These images are digitized by both cameras, each of which “sees” the marker spheres from a different angle. The software then uses this information to calculate the three-dimensional position of the instrument marker spheres relative to the position of the reference array marker spheres.
Translation - Spanish VV Spine es un sistema de navegación inalámbrico, lo cual significa que a diferencia de los sistemas de navegación convencionales, no necesita cables, ni pilas ni pedales. En lugar de ello, el sistema utiliza unas esferas marcadoras pasivas y dos cámaras de infrarrojos que emiten destellos de luz infrarroja.
Las esferas marcadoras pasivas se colocan en todos los instrumentos quirúrgicos y en un sistema de referencia fijado de forma segura a la estructura ósea del paciente. Cada esfera marcadora pasiva refleja los destellos de luz infrarroja que emiten las cámaras, lo cual da lugar a una imagen de reflexión infrarroja individual.
Ambas cámaras digitalizan estas imágenes y visualizan las esferas marcadoras desde un ángulo diferente. A continuación, el software utiliza esta información para calcular la posición tridimensional de las esferas marcadoras del instrumento respecto a la posición de las esferas marcadoras del sistema de referencia.
English to Spanish: Diastolic heart failure General field: Medical Detailed field: Medical: Cardiology
Source text - English Congestive heart failure (CHF), which is defined as the inability of the left ventricle to generate an adequate cardiac output at rest and during exercise while operating at normal left ventricular filling pressures, is usually associated with impaired left ventricular systolic function. However, symptoms of CHF may arise in the absence of any systolic abnormality. In these patients, contractile function is normal or even enhanced, and diastolic dysfunction is the principal cause of the classic symptoms of dyspnea and fatigue (1-4).
With abnormal diastolic function, the left ventricle is stiff and does not fill adequately at normal diastolic pressures. This leads to either decreased left ventricular end-diastolic volumes with a fall in cardiac output or a compensatory rise in left ventricular filling pressure to maintain cardiac output, which can lead to pulmonary venous hypertension. This syndrome has been termed diastolic heart failure.
The prevalence of diastolic heart failure in the community is unknown. Among patients with symptoms of CHF, systolic performance is normal in 14 % to 41 % (5-8). Heart failure caused by diastolic dysfunction is particularly high in elderly patients (5).
Translation - Spanish La insuficiencia cardíaca congestiva (ICC), que se define como la incapacidad del ventrículo izquierdo para generar un gasto cardíaco adecuado en reposo y durante el esfuerzo mientras funciona con presiones de llenado del ventrículo izquierdo normales, se asocia a la función sistólica ventricular izquierda anómala. No obstante, los síntomas de la ICC pueden aparecer sin que haya ninguna anomalía sistólica. En estos pacientes, la contractilidad es normal o incluso está aumentada, y la disfunción diastólica es la principal causa de los síntomas clásicos de disnea y fatiga (1-4).
Como consecuencia de la función diastólica anómala, el ventrículo izquierdo está rígido y no se llena bien a presiones diastólicas normales. Esto comporta una disminución de los volúmenes de fin de diástole del ventrículo izquierdo con un descenso del gasto cardíaco o un aumento compensatorio en la presión de llenado del ventrículo izquierdo para mantener el gasto cardíaco, que puede provocar hipertensión venosa pulmonar. Este síndrome se ha denominado insuficiencia cardíaca diastólica.
Se desconoce la prevalencia de esta patología en la población. En pacientes con síntomas de ICC, la función ventricular es normal entre un 14 % y un 41 % (5-8). La insuficiencia cardíaca provocada por la disfunción diastólica es especialmente frecuente en pacientes de edad avanzada (5).