The MP111 is a dying gasp storage and release controller. It charges storage capacitor from the input during normal operation. Once the storage capacitor is charged to the selected voltage, the charge is stopped, and the storage capacitor is separated from the input. The charging circuit maintains the storage voltage after the charge is completed.
Proposed translations
(Polish)
4 +1 | sterownik sygnału zaniku zasilania (funkcja "dying gasp") i ładowania kondensatora podtrzymującego | Crannmer |
Proposed translations
+1
4 days
Selected
sterownik sygnału zaniku zasilania (funkcja "dying gasp") i ładowania kondensatora podtrzymującego
Wyjaśnienie w dyskusji.
--------------------------------------------------
Note added at 4 Tage (2023-04-08 14:55:45 GMT)
--------------------------------------------------
ew. z odwróconą kolejnością funkcji
sterownik ładowania kondensatora podtrzymującego (funkcja "dying gasp") i sygnału zaniku zasilania
--------------------------------------------------
Note added at 4 Tage (2023-04-08 14:55:45 GMT)
--------------------------------------------------
ew. z odwróconą kolejnością funkcji
sterownik ładowania kondensatora podtrzymującego (funkcja "dying gasp") i sygnału zaniku zasilania
4 KudoZ points awarded for this answer.
Comment: "dzięki!"
Discussion
Poparcie dla odpowiedzi Tadeusza50 pozostaje w mocy.
7.1.2.5.3 fbit3 = ps (Power Status)
The power status bit ps is used to indicate the status of the local power supply in the STU-R. The power status bit is set to 1 if power is normal and to 0 if the power has failed. On loss of power at the STU-R, there shall be enough power left to send the ps bit in at least one and preferably three consecutive frames towards the STU-C. Note that, in the event of a power failure, the ps bit should be set to 0 for as many frames as possible before deactivation. If the ps bit is set for less than three frames, it is up to the application at the STU-C to determine the validity of the message. Regenerators shall pass this bit transparently. In M-pair mode, ps on Pair 1 shall carry the primary power status indication. The ps bit on all other pairs shall be duplicates of the Pair 1 ps bit.
T-REC-G.991.2-200312-I!!PDF-E.pd
sterownik wyzwalania sygnału zaniku zasilania (dying gasp) i ładowania kondensatora podtrzymującego
MP111DS-LF-P
MP111DS-LF-Z
MP111DS-LF
MP111XN
- https://www.monolithicpower.com/en/mp111.html
---
https://www.mfgchips.pl/products/MPS(Monolithic-Power-System...
https://www.yic-electronics.pl/pdf/MP111DS-LT-Z.html
Nie zgłaszam bo pewność bardzo mała a z "1" nie ma sensu.